A high efficiency furnace uses two heat exchangers and can be identified by its use of low-temp PVC for the exhaust, the use of an inducer fan and the presence of a condensation line to dispose of acidic condensate produced in the process of extracting heat from the combusted gasses, lennox pulse furnace.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website. Lennox Industries Inc. According to Bob Schjerven, president and chief operating officer for Lennox, dealers reported increased instances of corrosion in some Pulse furnace heat exchangers in units installed before The Lennox company urges owners of Lennox Pulse furnaces installed between and to schedule a furnace and safety check with an independent Lennox dealer.

Lennox pulse furnace

This problem started last year, and the furnace is now six years old. So far the repairman, in two trips, has replaced the "flapper," checked the gas pressure and cleaned the filter. He has also checked the thermostat anticipation setting, which is. I have tried setting the thermostat way up, thinking that when it first comes on, it might somehow vibrate off when the furnace comes on. No luck with that either. The exterior exhaust and air intake are not in any way blocked, and there is nothing around these pipe which would cause the exhaust fumes to be drawn back into the intake. There is one other symptom which may or may not be associated with the problem. The pulsing of the furnace is uneven whereas, as I recall, it sounded with a steady hum when the furnace was first installed. I would appreciate any ideas on this one before I call the repairman again. Unfortunately your furnace is a pig to work on. Non Lennox dealers don't have the knowledge to trouble shoot them. Do yourself a long term favor and junk it. Parts are unique and expensive for this furnace plus it's far and few between to where you will find that certain tech that can troubleshoot and repair this furnace the first time out.

There isn't much to compete for and you will find your HVAC guy raising lennox pulse furnace etc Contact information for Lennox industries, in Dallas Texas:. Next is the purge blower.

Please enter the name by which you would like to log-in and be known on this site. Please enter a password for your user account. Note that passwords are case-sensitive. Remember Me? Page 1 of 3 1 2 3 Last Jump to page: Results 1 to 20 of Thread: Lennox Pulse. Thread Tools Show Printable Version.

Lennox Industries Inc. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website. Watch out : Lennox, dealers reported increased instances of corrosion in some Pulse furnace heat exchangers in units installed before A corroded heat exchanger that leaks can be unsafe, even fatal. On by mod - InspectAPedia.

Lennox pulse furnace

Heat is even throughout your home, with no cold spots. If it sounds perfect, it's because it is. When a gas furnace is installed with a compatible Lennox heat pump, it creates a heating system that can switch back and forth between electricity and gas automatically, based on whichever is the most cost-efficient for the weather conditions at the time. SilentComfort also features a specially designed fan guard and fan blades to reduce air noise and sound levels. It is behind the scene silently keeping this older house super comfortable We have gone through one month with a substantial savings in gas consumption, could be close to half the cubic feet of gas for the degree days experienced this month. If you live elsewhere in the U.

M&p motorcycles

Next is the purge blower. Email Address: Please enter a valid email address for yourself. The worst thing that can happen is to give advice that kills people. Carl, admirable and creative, but remember to Watch out : you are betting your life and the lives of other building occupants on your DIY procedure; the worry is that we don't know what we don't know about heating system safety and testing. On by mod - DIY testing of heating system safety can be dangerous. Thread: Lennox Pulse. If you have one of these units and are not sure if it is an earlier or later model, you can tell by looking at the data card located on the inside wall of the furnace. Also, make sure the purge motor is working. Do you have to be certified to work on them? What is so scary about a Lennox Pulse furnace.

Lennox Industries Inc. InspectAPedia tolerates no conflicts of interest.

Prior to the furnace's attempt to start I heard what I would guess is a purging fan start up. As I am not a Lennox dealer I've stated this before I am occasionally found on a service call with one. Note that passwords are case-sensitive. If you can't get the parts or haven't spent hours of diagnosing the stupidest little things a pulse can do - stay away. If no voltage is present then, the motor is probably fine. Often, the systems we encounter are not installed according to published standards. But that may be due to the fact that were not a Lennox dealer I dunno. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. Lennox Pulse furnaces. If we get this thing solved I will advise what the fix was.

2 thoughts on “Lennox pulse furnace

  1. I am sorry, that I interrupt you, but, in my opinion, there is other way of the decision of a question.

  2. I am am excited too with this question. Tell to me, please - where I can find more information on this question?