rexroth indradrive error codes

Rexroth indradrive error codes

Obsolete industrial electronics forum is still alive and well, just undergoing some maintenance and more anti spam stuff, stand by for a better experience. We use both first and third-party cookies on this website.

When an error flashes on the control panel, you can clear the error message by resetting or using the Esc button. However, if the error state still exists, the error message will immediately begin flashing again. If, for example, you see error code F, Incorrect Ethernet configuration, you will have to correct the ethernet configuration before you can continue using your IndraDrive C. The intelligent operating panel has a programming function which supports device swap without a PC. Digital inputs and outputs as well as analog input on board. In line with newer Rexroth lines, the IndraDrive C is energy efficient and features drive-integrated safety technology. We can provide a manual for IndraDrive C.

Rexroth indradrive error codes

Go to Solution. This is a collection of popular fault codes that were searched for on another Rexroth online forum that has since been shut down. The best place to find fault code information is to download IndraWorks Ds with the drive help files. You can find this on our main website, under any IndraDrive page in the Downloads section. Here is one location that works today: IndraDrive Cs Drives. You can also find the download on the IndraWorks Engineering page. Install this on your PC and you will have full html help files for IndraDrive firmware including a complete listing of fault codes, their explanation and possible remedies. A short description of some fault codes are listed here, primarily to aid search engine request to find the information. The accepted responses from the forum are included but again, the most accurate resource is the Help Files in IndraWorks Ds. F - Loss of encoder 1 reference - This means that the motor encoder needs to be referenced with internal drive command Set Absolute Reference. It can be done directly with the commissioning software or with external controller. E and F - Question: After change ball bearing on servo motor, on servo drive appear error and F - Answer: Is it a Rexroth motor and if so, was it repaired at a Rexroth facility? It seems that the encoder may have been damaged or incorrectly re-connected during the repair.

A few examples are:.

The Indradrive is a generational jump for Rexroth Electric Drives and Controls, and there are distinct differences between Indradrive and Indramat. One of the differences is the much greater number of error messages available to Indradrive, and the corresponding higher granularity of initial troubleshooting available. While the older series drives had a 4 digit or less alphanumeric error code that would show up on the H1 display, the Indradrive series has a 5 digit display. Some of the old favorites are still here bb still means Drive Healthy , but there are a whole wealth of new error codes available. Watchdog triggers, Processor crash, firmware corruption are all in F9xxx.

At the core of many manufacturing and industrial tasks is the Rexroth IndraDrive. But, if you stumble upon fault codes in your drive interface without proper understanding, it can be intimidating. We can make things easier by breaking down frequently observed fault codes, explaining their possible origins, and providing solutions. In the event of such errors, the drive's safety measures get disabled, drive torque is immobilized, and following a diagnostic message display, the power is terminated. It's imperative to reboot the system to restore its operation.

Rexroth indradrive error codes

When an error flashes on the control panel, you can clear the error message by resetting or using the Esc button. However, if the error state still exists, the error message will immediately begin flashing again. If, for example, you see error code F, Incorrect Ethernet configuration, you will have to correct the ethernet configuration before you can continue using your IndraDrive C. The intelligent operating panel has a programming function which supports device swap without a PC. Digital inputs and outputs as well as analog input on board. In line with newer Rexroth lines, the IndraDrive C is energy efficient and features drive-integrated safety technology. We can provide a manual for IndraDrive C. Just use our Manual Request form.

Game of thrones kingdom names

A few instances are:. We offer phone and field support, factory repair, and factory reman. C03 act. Table Of Contents. An error occurred when writing a default value. Cause Remedy Mains contactor could not be switched Replace device Contactor monitor has detected an error When these arise, they enable users to determine the drive's action via suitable parameter configurations. Cause Remedy in the P, Holding brake control word activate the brake in the P, Holding brake Cause Remedy Heavy axis motion due to too high drive torque or Some of the old favorites are still here bb still means Drive Healthy , but there are a whole wealth of new error codes available. Note: If the safety function "safety related standstill" is active, this is displayed on the control panel of the drive with "SH" See also documentation of the respective supply unit Fill Out Fault Report A fault report form to be copied can be found in the documentation of the respective supply unit. If the application and safety allows for it, switch the cable from one drive to another. The diagnostic message number is contained in the S, Diagnostic message number parameter in hexadecimal form for this example: 0x00F We will do everything we can to get you up and running again without delay.

Table Of Contents.

There are different causes and remedies for both device Cause Remedy At least one of both probes was activated in A better title for these errors would be Control Interface Errors. The "C14" display signals that the command is executed. Solutions involve reengaging mains voltage or lightening the power supply load. I believe I got a hard copy when we did the installation but I'm not positive. Table Of Contents. Delete bookmark? Designated trademarks, brand names, and brands appearing herein are the property of their respective owners. Here are some specific error instances: F — Internal Function Call Error : This indicates a broad software malfunction. The drive automatically switches to safety related standstill and the output stage is switched off via two channels. Sign In OR.

1 thoughts on “Rexroth indradrive error codes

Leave a Reply